What is the operating procedure for a resistance screening machine?
What is the operating procedure for a resistance screening machine? ?

A resistance tester is an instrument used to measure the electrical conductivity of objects. Resistance testers are widely employed in electrical safety inspections and as-built checks for grounding systems. They come in various types, including ground resistance testers, insulation resistance testers, DC resistance testers, surface resistance testers, and loop resistance testers. Resistance testers are indispensable tools for electrical safety assessments and for the acceptance inspection of grounding projects. These include ground resistance testers, insulation resistance testers, DC resistance testers, surface resistance testers, and loop resistance testers. Loop resistance testers—such as transformer loop resistance testers—are suitable for measuring contact resistance at the main contacts of high- and low-voltage switches, as well as the DC resistance of high- and low-voltage cable circuits. Intelligent loop resistance testers utilize… 100 A constant-current output. The output voltage is 10 V—2 to 3 times that of conventional instruments—allowing the use of fine‑gauge test leads on the load surface, which significantly reduces the workload of field testers. The testing process is fully automated under microcontroller control, offering high accuracy, excellent repeatability, one‑button operation, and simple handling, with test data displayed on an LCD screen. It is suitable for a variety of working environments. The ground resistance tester is a widely used instrument for testing and measuring earth resistance. In recent years, driven by rapid advances in computer technology, ground resistance testers have increasingly incorporated microprocessor‑based innovations, delivering measurement capabilities, functionality, and accuracy that far surpass those of conventional devices.
The DC resistance tester is a next-generation device for measuring the DC resistance of transformers. It can automatically select the appropriate test current based on the type of power transformer and display the results rapidly. The instrument also features data storage, printing, and discharge‑indication functions, with a built-in non‑volatile memory that enables long‑term retention of measurement data. Its LCD display provides an excellent human–machine interface, making it an ideal tool for DC resistance testing.
A ground resistance tester is used to measure the resistance of underground grounding electrodes and the stray soil‑borne current resistance, typically with a ground resistance meter (or a ground resistance megohmmeter). Its appearance is similar to that of a standard insulation megohmmeter, and by convention it is also referred to as a ground resistance megohmmeter. The shape and structure of Type A megohmmeters vary slightly depending on the model, but their operating procedures are essentially the same. Two grounding probes and three conductors are connected to the earth‑resistance meter. The method of use and measurement steps are as follows:
( a) Ground resistance screening machine (b) Connecting cable (c) Measuring ground rod
1. Remove the connection between the grounding main and the grounding electrode, or remove all connection points of the grounding branch circuits on the grounding main.
2. Drive two grounding rods into the ground to a depth of 400 mm, with one rod located 40 m from the grounding electrode and the other 20 m from the electrode.
3. Place the megohmmeter on a flat surface near the grounding electrode, then proceed with wiring.
( 1) Use a connecting lead to link terminal E on the instrument to grounding electrode E’ of the grounding system.
( 2) Use a connecting cable to link terminal C on the instrument to grounding rod C’ located 40 meters from the grounding electrode.
( 3) Use a connecting lead to link terminal P on the instrument to grounding rod P′, which is located 20 meters from the grounding electrode.
4. Adjust the coarse adjustment knob according to the required grounding resistance of the device under test (there are three adjustable ranges).
5. Shake the megger uniformly at approximately 120 rpm. When the grounding electrode needle deflects, immediately adjust the fine‑adjustment dial until the needle is centered. The measured grounding resistance of the electrode is obtained by multiplying the reading on the fine‑adjustment dial by the coarse‑adjustment multiplier. For example, if the fine‑adjustment reading is 0.6 and the coarse‑adjustment multiplier is 10, the measured grounding resistance is 6 Ω.
6. To ensure the reliability of the measured grounding resistance, the measurement direction should be changed and the test repeated. The average of several measurements shall be taken as the grounding resistance of the grounding electrode. 。
Contact Us
Contact: Ouyang Yu
Mobile: +8615362460536
Email: mkt01@seeney.cn
Headquarters Address: 8th Floor, Building 1, Xini Science and Technology Park, No. 132 Tanlong North Road, Tanzhou Town, Zhongshan City, Guangdong Province
Related Recommendations
Non-standard custom equipment for loading and unloading operations
SN-VR-C12 Series
SN-VR-C18 Series
SN-VR-CT2 Series
A professional provider of machine vision solutions
Professionalism highlights excellence; strength forges quality.
Contact Information
Contact: Ouyang Yu
Mobile : +8615362460536
Email: mkt01@seeney.cn
Headquarters Address: 8th Floor, Building 1, Xini Science and Technology Park, No. 132 Tanlong North Road, Tanzhou Town, Zhongshan City, Guangdong Province
© 2026 Guangdong Seeney Technology Co., Ltd. All rights reserved
Technical Support:Chinese Enterprises' Cross-Border Operations SEO
E-mail:
联系电话:
微信:
在线客服添加返回顶部
屏蔽手机端访问
右侧在线客服样式 1,2,3 1
图片alt标题设置: Guangdong Seeney Technology Co., Ltd.
表单验证提示文本: Content cannot be empty!
循环体没有内容时: Sorry,no matching items were found.
CSS / JS 文件放置地